Expand Analog I/O Using Dante. For use with Symetrix Radius, Prism and Edge DSPs, the Symetrix xOut 12 Dante I/O Audio Expander uses Composer for setup. Using Composer eliminates switches, circuit board jumpers, and mechanical adjustments as well as the need for third party software applications.
Symetrix xOut 12 Dante I/O Audio Expander Features
- 1/2 Rack Form Factor
- PoE – injectors included
- xIn 4 – 4 analog mic/line inputs
- xIO 4×4 – 4 analog mic/line inputs + 4 analog outputs
- xOut 4 – 4 analog outputs
- Optional rack and surface mounting kits sold separately
- xOut 12 Dante I/O Audio Expander1
- Sampling rate 48 kHz, ± 100 ppm.
- Frequency response (D/A) 20 Hz – 20 kHz, ± 0.5 dB.
- Channel separation (D/A) > 111 dB @ 1 kHz, +24 dBu.
- Dante cable Standard CAT6, maximum device to device length = 100 meters.
- Connectors 3.81 mm terminal blocks.
- Number of outputs Twelve (12) balanced line level.
- Nominal output level +4 dBu with 20 dB of headroom.
- Maximum output level +24 dBu (+22.8 dBu into a 2k Ohm minimum load).
- Output Impedance 300 Ohms balanced, 150 Ohms unbalanced.
- Dynamic Range > 118 dB, A-weighted.
- THD+Noise < -105 dB, unweighted; 1 kHz @ +22 dBu with 0 dB gain.
- Latency 0.60 mS.
- Mechanical Data
- Space Required: 1U (WDH: 18.91 in x 9.5 in x 1.72 in / 48.02 cm x 24.13 cm x 4.37 cm). Depth does not include connector allowance. Allow at least 3 inch additional clearance for rear panel connections. Additional depth may be required depending upon your specific wiring and connections.
- Electrical: 100-240 VAC, 50/60 Hz, 25 Watts maximum universal input. No line voltage switching required.
- Ventilation: Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed (5.08 cm, 2 in. minimum clearance). The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc.
- Shipping Weight: 12 lbs. (5.4 kg).
- Certifications or Compliance: UL 60065, cUL 60065, IEC 60065, EN 55103-1, EN 55103-2, FCC Part 15, RoHS.